GEN5kW series

PROGRAMMABLE HIGH POWER DC-POWER SUPPLIES

programmierbares DC-Netzteil GEN5kW

The Genesys family of programmable power supplies sets a new standard for flexible, reliable, AC/DC power systems in OEM, Industrial and Laboratory applications.
Now available in more power levels (750W, 1.5kW, 3.3kW, 5kW, 10kW and 15kW) and with available output voltages from 7.5 to 600V, and current up to 1,000A. Active PFC, and universal input head a long list of standard features.
GenesysTM 5kW includes several other important new features and options. Up to four like units may be connected in parallel and user configured for the Master to Program and Monitor the total current of the group. Thus, four units can appear as a single 20kW power supply, increasing flexibility for system designers. In the Digital Options, a new option called Multi-Drop allows an IEEE Multi-Drop Master to control Multi-Drop equipped Slaves over RS-485, avoiding the cost of a GPIB board in every slave power supply. Up to 31 may be addressed over the RS-485 lines of Master and Slaves.
Approvals: CE Mark for LVD and EMC Regulation.

GEN 8-600 10-500 16-310 20-250 30-170 40-125 60-85 80-65 100-50 150-34 300-17 600-8.5
Uout (VDC) 8 10 16 20 30 40 60 80 100 150 300 600
Iout (ADC) 600 500 310 250 170 125 85 65 50 34 17 8.5
Pout (W) 4800 5000 4960 5000 5100 5000 5100 5200 5000 5100 5100 5100
SPECIFICATIONS

Input voltage/freq. (*1): 3-Phase 200VAC , 208VAC and 230VAC Models : 170~265VRMS , 47~63Hz
3-Phase, 400V models: 342~460VAC, 47~63Hz
Power Factor: 0.94 at 100% Load and 208V / 380V / 400V / 415V
Inrush Peak Current: 3-Phase 200V: 50A, 3-Phase 400V: 20A. Not including the EMI filter inrush current, less than 0,2ms
Efficiency (*2): 83% - 90%
Hold-up time (CV mode): 5ms Typical
Parallel Operation: Up to 4 identical units in master/slave mode
Series Operation: Up to 2 identical units. with external diodes. 600V Max to Chassis ground
Operating temp.: 0°C - 50°C, 100% load
Storage temp.: -20°C - 85°C
Operating humidity: 20 - 90% RH (no condensation)
Storage humidity: 10 - 95% RH (no condensation)
Vibration: MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface..
Shock: Less than 20G , half sine, 11ms. Unit is unpacked.
Altitude: Operating: 10000ft (3000m),Derate output current by 2%/100m above 2000m,
Non operating: 40000ft (12000m).
RoHS Compliance: Complies with the requirements of RoHS directive.
Cooling: Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis; Variable fan speed.
Dimensions (WxHxD): W: 423mm, H: 88mm, D: 442.5mm (excluding connectors,encoders,handles,etc.)
Weight: 16kg
AC Input connector (with Protective Cover): 3-Phase, 208V & 400V models, Power Combicon PC 6-16/4-GF-10,16 series, with Strain relief.
Output connectors: 8V to 100V models: Bus-bars (hole Ø 10.5mm). 150V to 600V models: wire clamp connector, Phoenix P/N: FRONT-4-H-7.62

*1: For cases where conformance to various safety standards (UL, IEC, etc›) is required, to be described as 190-240VAC (50/60Hz) for 3-Phase 208V models, and 380~415VAC (50/60Hz) for 3-Phase 400V models.

Options:

  • IEEE 488.2 (GPIB) Interface P/N: IEEE
  • Voltage Programming Isolated Analog Interface P/N: IS510
  • Current Programming Isolated analog interface P/N: IS420
  • LAN Interface (Complies with LXI Class C) P/N: LAN


Accessories:

Communication cable
RS232/RS485 Cable is used to connect the power supply to the Host PC.

Mode RS-485 RS-232 RS-232
  PC Connector   DB-9F   DB-9F   DB-25F
  Communication Cable   Shield Ground L=2m   Shield Ground L=2m   FShield Ground L=2m
  Power Supply Connector   EIA/TIA-568A (RJ-45)   EIA/TIA-568A (RJ-45)   EIA/TIA-568A (RJ-45)
P/N GEN/485-9 GEN/232-9 GEN/232-25

Serial link cable*
Daisy-chain up to 31 power supplies.

Mode Power Supply Connector Communication Cable P/N
RS-485 EIA/TIA-568A (RJ-45) Shield Ground L=50cm GEN/RJ45

* Included with the power supply