F series

Output up to 12kV 10W

high-voltage-supply F 3

The F Series is a broad line of small, versatile, DC to HVDC converters that provide up to 12,000VDC (±) at 10W continuous output power.
The output is proportional to the input voltage, and features a low 0.7VDC typical turn-on voltage.
Eighteen models are available covering the range of 0 to 100V through 0 to 12,000V, positive or negative. These modules exhibit very low EMI/RFI, noise and ripple by means of a quasi-sinewave oscillator, a fully enclosed transformer. input and output filtering, and a five sided metal enclosure.
The isolated output offers a lot of possibilities in configuring for negative or positive output polarity.

Options include two mounting holes and an output center-tap option which, when grounded, provides both positive and negative outputs from one compact, low cost module.

Features:

  • Low Ripple
  • Very Low EMI/RFI
  • Proportional Input / Output
  • PCB Mountable
  • Compact Package
  • Input/Output Isolation (Floating Output)
  • Center Tap Option
  • Convection Cooling / No Derating Required
  • Input/Output Filtering
  • Arc and Short Circuit Protection


Options:


Mounting Holes, add H to model number
       (Models F80-F121 come standard with holes)
 
Output Center Tap, add CT to model number
 
 

Applications:

  • Capacitor Charging
  • Spectometry
  • Piezo Devices
  • Lamp Ignition
  • Lamp Drive
  • Q Switches
  • Ion Pumps
  • Electro-Static Field Generation
  • Grid Bias
  • Electrophoresis
  • Lasers
Model Input Voltage
[VDC]
Output Voltage  *2
[VDC]
Max. Output Current  *4
[mA]
Ripple
p-p
F01 0 - 12 0 - 100 100 < 0.6%
F02 0 - 12 0 - 200 50 < 1.0%
F03 0 - 12 0 - 300 33.3 < 1.0%
F04 0 - 12 0 - 400 25 < 1.0%
F05 0 - 12 0 - 500 20 < 0.1%
F06 0 - 12 0 - 600 16 < 0.1%
F08 0 - 12 0 - 800 12.5 < 0.1%
F10 0 - 12 0 - 1,000 10 < 0.1%
F12 0 - 12 0 - 1,200 8.3 < 0.1%
F15 0 - 12 0 - 1,500 6.6 < 0.1%
F20 0 - 12 0 - 2,000 5 < 1.0%
F30 0 - 15 0 - 3,000 3.3 < 1.0%
F40 0 - 15 0 - 4,000 2.5 < 1.0%
F50 0 - 15 0 - 5,000 2 < 1.0%
F60 0 - 15 0 - 6,000 1.66 < 1.0%
F80* 0 - 15 0 - 8,000 1.25 < 2.5%
F101* 0 - 15 0 - 10,000 1 < 2.5%
F121* 0 - 15 0 - 12,000 0.83 < 2.5%

* This unit has flying output leads

Center tapped units supply both polarities with respect to a center-tap return
(e.g. F02CT: 0 to ±100VDC)

PHYSICAL CHARACTERISTICS:

  • F01-F60: 71.1 x 43.2 x 21.6 mm3
  • F80-F121: 71.1 x 43.2 x 24.1 mm3
  • Weight: 142g approx.
  • Packaging: Fully Encapsulated
  • Case material: Black Anodized Aluminium

ELECTRICAL SPECIFICATIONS*3:

  • Typical turn-on voltage: 0.7VDC
  • Input current (no load)*1: <500mA
  • Input current (full load)*1: <1.5A
  • Isolation (F01-F60): 3,500V + VOUT
  • Isolation (F80-F121): 500V + VOUT
  • Operating temp: -10°C to +70°C

*1 - At maximum rated output voltage

*2 - Output voltage is load dependent. Under light or no-load conditions, reduce the input voltage so maximum rated output voltage is not exceeded.

*3 - Specifications after 30 minutes warm-up, full load, at 25°C unless otherwise noted.

*4 - The rated output current is available at full output voltage and must be derated proportionally as the input voltage decreases. For example: a 500V, 1.5W unit, rated at 3mA at 500V will provide 1.5mA at 250V out.

Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!