E series

Output up to 12kV 3W

high-voltage-supply e 3

Applications:

  • Electro-Static Field Generation, HV Op Amps
  • Grid Bias, Spectrometry, Piezo Devices, Lamp Ignition
  • Q Switches, Ion Pumps
  • Capacitor Charging, Electrophoresis
  • Image Intensifiers, Printers


Features:


  • Low Ripple, Low EMI/RFI
  • Proportional Input / Output
  • Exceptional Reliability
  • Compact, PCB Mount Package
  • Input/Output Isolation (Floating Output)
  • Center Tap Option
  • Clearance Holes for Mounting
  • RoHS Compliant

Model Overview

Model Output Voltage Output Current Input Voltage Input Current
(No Load)
Input Current
(Full Load)
Ripple
E01 0 - 0.1kV 30mA 0 - 12V <175mA <400mA 0.2%
E02 0 - 0.2kV 15mA 0 - 12V <175mA <400mA 0.25%
E03 0 - 0.3kV 10mA 0 - 12V <175mA <400mA 1.0%
E05 0 - 0.5kV 6mA 0 - 12V <175mA <400mA 0.1%
E06 0 - 0.6kV 5mA 0 - 12V <175mA <400mA 0.1%
E08 0 - 0.8kV 3.7mA 0 - 12V <175mA <400mA 0.1%
E10 0 - 1kV 3mA 0 - 12V <175mA <400mA 0.05%
E12 0 - 1.2kV 2.5mA 0 - 12V <175mA <400mA 0.05%
E15 0 - 1.5kV 2mA 0 - 12V <175mA <400mA 0.05%
E20 0 - 2kV 1.5mA 0 - 12V <175mA <400mA 0.25%
E30 0 - 3kV 1mA 0 - 15V <175mA <400mA 0.25%
E40 0 - 4kV 0.75mA 0 - 15V <175mA <400mA 0.5%
E50 0 - 5kV 0.6mA 0 - 15V <175mA <400mA 0.5%
E60 0 - 6kV 0.5mA 0 - 15V <175mA <400mA 0.5%
E70* 0 - 7kV 0.43mA 0 - 15V <175mA <400mA 1.0%
E80* 0 - 8kV 0.25mA 0 - 15V <175mA <400mA 1.25%
E101* 0 - 10kV 0.2mA 0 - 15V <175mA <400mA 1.5%
E121* 0 - 12kV 0.16mA 0 - 15V <175mA <400mA 1.5%

* This unit has flying output leads

Center tapped units supply both polarities with respect to a center-tap return
(e.g. E02CT: 0 to ±100VDC)

 
SPECIFICATIONS
 
Input Voltage: See table
Typical Turn-On Voltage: 0.7V
Output Voltage: See table
Output Current: See table
Ripple: See table
Isolation E01-E60: 3.5kV +VOUT
        E70-E121: 500V +VOUT
Operating Temp E01-E60: -10°C to +60°C
        E70-E121: -10°C to +50°C
Weight: 85g approx.
Packaging: Fully Encapsulated
Case Material: Diallyl Phthalate (DAP)
Pins: 0.79mm Dia.,
5.1mm min. Length
 
 
OPTIONS
 
AB Shielding and Mounting Enclosure
CT Output Center Tap
 
 
Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!