W series

Output up to 40kV 350W

CO Series Digital Control Interfaces

High-Voltage-Supply - W
  • Compact, light weight
  • Remote programming and monitoring
  • Constant Voltage / Constant Current automatic crossover
  • High efficiency
  • Short circuit and arc protected
  • Wide output lineup

 
Applications:

  • Electron beam / ion beam
  • Electrophoresis / Bio
  • Automatic Test Equipment
  • X-ray inspection systems
  • Capacitor charging


The W series is a compact, high power module with AC input.
It is best suited for CRT evaluation, X-ray systems, and capacitor charging applications.
Equipped with full remote control capabilities and monitors, it features a wide range of outputs from 500V to 40kV / 120W to 350W.

120 Watt
Output Voltage Output Current Ripple Model
0 - 0.5kVDC 0 - 240mA 0.2% W1-0.5*
0 - 1kVDC 0 - 120mA 0.2% W1-1*
0 - 3kVDC 0 - 40mA 0.2% W1-3*
0 - 5kVDC 0 - 24mA 0.2% W1-5*
0 - 10kVDC 0 - 12mA 0.2% W1-10*
0 - 20kVDC 0 - 6mA 0.2% W1-20*
0 - 30kVDC 0 - 4mA 0.5% W1-30*
0 - 33kVDC 0 - 3.5mA 0.5% W1-33*
0 - 35kVDC 0 - 3.3mA 0.5% W1-35*
0 - 40kVDC 0 - 3mA 0.5% W1-40*
200 Watt
Output Voltage Output Current Ripple Model
0 - 0.5kVDC 0 - 400mA 0.5% W2-0.5*
0 - 1kVDC 0 - 200mA 0.2% W2-1*
0 - 3kVDC 0 - 67mA 0.2% W2-3*
0 - 5kVDC 0 - 40mA 0.2% W2-5*
0 - 10kVDC 0 - 20mA 0.2% W2-10*
0 - 20kVDC 0 - 10mA 0.2% W2-20*
0 - 30kVDC 0 - 6.7mA 0.5% W2-30*
0 - 40kVDC 0 - 5mA 0.5% W2-40*
300 Watt, 350 Watt
Output Voltage Output Current Ripple Model
0 - 0.5kVDC 0 - 700mA 0.5% W3-0.5*
0 - 1kVDC 0 - 350mA 0.3% W3-1*
0 - 1.5kVDC 0 - 200mA 0.3% W3-1.5*
0 - 3kVDC 0 - 117mA 0.3% W3-3*
0 - 5kVDC 0 - 70mA 0.3% W3-5*
0 - 10kVDC 0 - 35mA 0.3% W3-10*
0 - 20kVDC 0 - 17.5mA 0.3% W3-20*
0 - 30kVDC 0 - 11.7mA 0.5% W3-30*
0 - 40kVDC 0 - 8.7mA 0.5% W3-40*

* P for Positive, N for Negative Polarity

SPECIFICATIONS

Input Voltage: 115VAC ±10%, 50/60Hz
100VAC, 200VAC, 230VAC ±10% (options)
Output Control: Via external voltage source 0V to 10V
or external 5kΩ potentiometer
Voltage Regulation: Line: ±0.02% (of max. voltage for Input ±10% change)
Load: 0.02% (of max. voltage for full load change)
Current Regulation: Line: ±0.1% (of max. current for Input ±10% change)
Load: 0.2% (of max. current for full load change)
Stability: 0.02%/h, 0.05%/8h (at voltage operation)
0.05%/h, 0.1%/8h (at current operation)
Temperature Coeff.: 0.02%/°C (at voltage operation)
0.05%/°C (at current operation)
Operating Temp.: 0°C to +50°C
Storage Temp.: -40°C to +85°C
Monitor Output: 0V to 10V, ±1%
(at max. rated output)
High Voltage ON/OFF: Short = HV ON
Open = HV OFF
Protection: Protection against overvoltage, over current, short circuit, arc and over temperature
Efficiency: 80% typ.

  

REMARKS

These units do not bear the CE-mark. They are intended to be used as components within systems. The customer is responsible for keeping the applicable EMC- and safety-standards.

ACCESSORIES

AC Input Cable         2.5m 3-wire line cord
HV OutputCable       2.5m HV shielded cable
Signal Connector     Subminiature D-type connector 25 pin

OTHER FUNCTIONS

  • Voltage, Current Program (0-10V, 0-5kΩ)
  • Voltage, Current Monitor (0 - 10V)
  • HV ON/OFF
  • Interlock
  • HV status
  • 10.24V reference

OPTIONS

 L(100V)     Input Voltage
                    100VAC ±10%
 L(200V)     Input Voltage
                    200VAC ±10%
 L(230V)     Input Voltage
                    230VAC ±10%


Note: These specifications are at the maximum rated output after a warm-up period unless otherwise specified.