HiPot & Safety Tester

Main application fields of the HiPot Safety Tester are AC/ DC/ IR hipot tests for electronic components, ground bond- and leakage current tests at electric and medical devices.
Further usage is for UL, CE, TüV conformity tests.


Safety Analyzer / HiPot Tester 19032 19050 19071 19073 19572
Voltage Test - Output AC 0.05~5 kV 0.05~5 kV 0.05~5 kV 0.05~5 kV -
Voltage Test - Output DC 0.05~6 kV 0.05~6 kV - 0.05~6 kV -
Isolation Resistance Test Output Voltage DC:
0.05~1 kV
DC:
0.05~1 kV
- DC:
0.05~1 kV
-
Ground Resistance Test Output Current AC:
3~30 A
- - - AC:
3~45 A


Electrical Safety Analyser 19032/19032-P

  • Floating Output Design meet EN50191 (19032-P)
  • 500VA Power Rating (19032-P)
  • Five instruments in one: AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
  • Programmable output voltage to 5kV AC and 6kV DC
  • Insulation resistance to 50GΩ/1000V DC
  • Ground bond up to 30A (Option up to 40A / 60A)
  • Open/Short check(OSC)
  • ARC detection (Flashover)
  • Password Protected front panel lockout
  • Storage of 50 Tests Setups with 100 Steps per setup
  • Optional dynamic leakage current auto scanning (A190305/A190306/A190307/A190308)
  • Standard RS-232 Interface
  • Standard GB OFFSET KIT, SCANNER Interface
  • Optional GPIB Interface


HiPot Tester 19050 Series

  • 3 in 1 Tester : AC, DC, IR
  • Programmable output voltage to 5kV AC and 6kV DC
  • Trip current programmable to 30mA AC and 10mA DC
  • Insulation resistance to 50GΩ/1000V DC
  • Built-in 8 channel SCANNER (19053 only)
  • Built-in 4 channel SCANNER (19054 only)
  • Open/Short Check (OSC)
  • Ground Continuity Check
  • ARC detection (Flashover)
  • Storage of 50 Tests Setups with 100 Steps per setup
  • Fast cutoff time: 0.4 ms, fast discharge time: 0.2 sec
  • Standard RS-232 Interface
  • Optional GPIB Interface


HiPot Tester 19070 Series

  • Compact size Hipot tester
  • Three instruments in one: AC Hipot, DC Hipot, Insulation Resistance (19073)
  • Open/Short Check (OSC)
  • ARC detection (Flashover)
  • Fast cut-off: 0.4 ms, fast discharge: within 0.2 sec
  • Provide reliable and stable test results
  • Storage of 10 Tests Setups with 60 Steps per setup
  • Ground Fault Interrupt (GFI)


Ground Bond Tester 19572

  • Wide resistance measurement range : 0.1 ~ 510 mΩ
  • High performance AC current output : 45 A
  • Compact size ground bond tester
  • Provide reliable and stable test results
  • Built-in resistance compensation function
  • Standard RS-232 interface
  • Optional GPIB Interface
  • Compatible with the model 19070 series Hipot Tester