GP series

Output up to 6kV 1W

high-voltage-supply GP

Applications:

  • Portable, Battery Powered Applications
  • Sustaining Ion Pumps
  • Vacuum Gauges
  • Photomultiplier Tubes
  • Spectrometry, Electrostatic Chucks, Lamp Ignition
  • Displays, Non-impact Printers
  • Electrostatic Field Generation, Avalanche Photodiodes
  • Piezo Devices, Electrophoresis


Features:

  • Low Power Consumption
  • Small Case Size
  • Light Weight
  • Short Circuit Protection
  • Low EMI/RFI
  • Input/Output Isolation (Floating Output)
  • Center Tap Option
  • Low Cost / High Performance
  • MTBF: >2.31 million hrs per Bellcore TR-332

The GP Series is a line of miniature, DC to HV DC converters providing 0.1kVDC to 6kVDC, positive or negative, in a compact PCB mount package.
This line features low power consumption, making it ideal for portable, battery powered applications.
The isolated output is proportional to the input, and is linear from approximately 0.7 V in.
A low noise quasi-sinewave oscillator and shielded transformer provide clean, reliable DC to HV DC conversion with low EMI and RFI. The isolated output allows for user selectable output polarity.
No minimum load is required.

Model Output *3
Voltage
Output *5
Current
Input Voltage Input *2
Current
(No Load)
Input *2
Current
(Full Load)
Ripple
GP01 0 - 0.1kV 10mA 0 - 12V <45mA <150mA <0.75%
GP02 0 - 0.2kV 5mA 0 - 12V <45mA <150mA <1.75%
GP03 0 - 0.3kV 3mA 0 - 12V <45mA <125mA <0.50%
GP05 0 - 0.5kV 2mA 0 - 12V <15mA <125mA <0.50%
GP06 0 - 0.6kV 1.66mA 0 - 12V <15mA <125mA <0.50%
GP08 0 - 0.8kV 1.25mA 0 - 12V <25mA <125mA <0.75%
GP10 0 - 1kV 1mA 0 - 12V <15mA <125mA <0.75%
GP12 0 - 1.2kV 840µA 0 - 12V <15mA <125mA <0.75%
GP15 0 - 1.5kV 660µA 0 - 12V <20mA <125mA <0.75%
GP20 0 - 2kV 500µA 0 - 12V <30mA <130mA <0.75%
GP25 0 - 2.5kV 400µA 0 - 12V <30mA <130mA <1.00%
GP30 0 - 3kV 340µA 0 - 12V <40mA <130mA <1.00%
GP40 *1 0 - 4kV 250µA 0 - 12V <50mA <130mA <1.00%
GP50 *1 0 - 5kV 200µA 0 - 12V <70mA <150mA <1.50%
GP60 *1 0 - 6kV 166µA 0 - 12V <85mA <175mA <1.00%

*1 Caution: Models GP40, GP50 & GP60 do not have internal bleeder resistors on the output.
      Provisions must be made externally to discharge the output capacitors if this feature is desired.
*2 At maximum rated output voltage.
*3 Output Voltage is load dependent. Under light or no load conditions, reduce input
      voltage so maximum rated output voltage is not exceeded.
*4 Specifications after 30 minutes warm-up, full load, at 25°C unless otherwise noted.
*5 The rated output current is available at full output voltage and must be derated
      proportionally as the input voltage decreases.
      For example: a 500V, 1.5W unit, rated at 3mA at 500V will provide 1.5mA at 250V out.


SPECIFICATIONS
 
Input Voltage: See table
Typical Turn-On Voltage: 0.7 V
Output Voltage Tolerance
(Full Load, 12V in, +25°C):

+1%, -5%
Output Current: See table
Ripple: See table
Operating Temp: -20°C to +70°C
Storage Temp: -20°C to +105°C
Load Regulation: <10% (No Load to Full Load)
Isolation: 3.5kV+Vout
Weight: 40 g approx.
Packaging: Fully Encapsulated
Case Material: Glass-filled Epoxy
Pins: 0.79mm Diameter,
5.1mm Long

OPTIONS

-R RoHS compliant
Epoxy: A.  Low Outgassing (NASA approved per ASTM E-959-93)
B.  UL 94 V0 flammability rating

ACCESSORIES

AB External Mounting Box


*Specifications are subject to change without notice